Aller au contenu
|
Français 
| Contact us 

OBIGGS for helicopter  [ Return towards  On-board inert gas generating systems  ]

Protection of the helicopter fuel tanks against any risk of fire or explosion

The OBIGGS is a simple equipment generating directly Nitrogen on board to fully protect the helicopter tanks against explosion. Autonomous, it does not require any logistics.

 (© Air Liquide / Photo Patrick Avavian)Based on a hollow fiber separation process, the OBIGGS allows to produce during the mission the flow of Nitrogen Enriched Air (NEA) requested to protect the helicopter. Part of the oxygen contained in the fuel tank is replaced by Nitrogen, keeping the vapours non-flammable.

The OBIGGS includes a Temperature Control System, a filter, a pressure controller, an oxygen sensor and a separation module. Hence, compressed air is directly tapped on Helicopter engine air and transformed into NEA that can be directly distributed in the fuel tanks. Compact, the Air Liquide OBIGGS can be easily installed on the Helicopter. Besides, Air Liquide can support the customer to design the distribution system: Inerting modelling, piping sizing, supply of distribution components. The use of the OBIGGS does not need any calibration or logistic operation before the flight. By means of the control of a selected set of signals generated by the OBIGGS, the crew is permanently aware of the status of the equipment.

Range

 

Light helicopter

Large helicopter

Weight

< 4.5 kg

< 12 kg

Flow

0.15 lb/min

0.4 lb/min

NEA quality

up to 4 % O2

up to 7 % O2

Power supply

28 Vdc - 115 Vac  / 400 Hz

28 Vdc - 115 Vac / 400 Hz

Key benefits

  • Compact lightweight system: Simple integration
  • No calibration nor logistic
  • Reduced schedule maintenance
  • Full Air Liquide support for OBIGGS integration and gas distribution design

key technical characteristics

  • Separation by MEDAL hollow fibers membrane
  • Temperature Management System (TMS) allowing to use bleed air with temperatures up to 400°C
  • Integrated controller including a pressure regulator, a shut-off valve, a flow regulator and an oxygen analyser

Standard

  • Qualified according to MIL-STD standards

References

Contacts

For any further information, contact us:

Monique Thomachot
Sales - Breathing equipment
Tel: +33 (0) 4 76 43 60 10

Nathalie Ray 
Sales department
Tel: +33 (0) 4 76 43 62 11

By e-mail :

Click here

Jobs Search and Apply

Careers@Air Liquide

See detail

gas encyclopedia

Properties of 138 gases

See detail